Class: OpenStudio::Model::Model
- Inherits:
-
Object
- Object
- OpenStudio::Model::Model
- Defined in:
- lib/buildingsync/helpers/Model.hvac.rb
Overview
Model class
Instance Method Summary collapse
-
#add_cbecs_hvac_system(standard, system_type, zones) ⇒ Object
Adds the HVAC system as derived from the combinations of CBECS 2012 MAINHT and MAINCL fields.
Instance Method Details
#add_cbecs_hvac_system(standard, system_type, zones) ⇒ Object
Adds the HVAC system as derived from the combinations of CBECS 2012 MAINHT and MAINCL fields. Mapping between combinations and HVAC systems per www.nrel.gov/docs/fy08osti/41956.pdf Table C-31
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 |
# File 'lib/buildingsync/helpers/Model.hvac.rb', line 13 def add_cbecs_hvac_system(standard, system_type, zones) case system_type when 'PTAC with hot water heat' standard.model_add_hvac_system(self, 'PTAC', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones) when 'PTAC with gas coil heat' standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = 'NaturalGas', cl = 'Electricity', zones) when 'PTAC with electric baseboard heat' standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, zones) when 'PTAC with no heat' standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = nil, cl = 'Electricity', zones) when 'PTAC with district hot water heat' standard.model_add_hvac_system(self, 'PTAC', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones) when 'PTHP' standard.model_add_hvac_system(self, 'PTHP', ht = 'Electricity', znht = nil, cl = 'Electricity', zones) when 'PSZ-AC with gas coil heat' standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones) when 'PSZ-AC with electric baseboard heat' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, zones) when 'PSZ-AC with no heat' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'Electricity', zones) when 'PSZ-AC with district hot water heat' standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones) when 'PSZ-HP' standard.model_add_hvac_system(self, 'PSZ-HP', ht = 'Electricity', znht = nil, cl = 'Electricity', zones) when 'Fan coil district chilled water with no heat' standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones) when 'Fan coil district chilled water and boiler' standard.model_add_hvac_system(self, 'Fan Coil', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', zones) when 'Fan coil district chilled water unit heaters' standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, zones) when 'Fan coil district chilled water electric baseboard heat' standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, zones) when 'Fan coil district hot and chilled water' standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', zones) when 'Fan coil district hot water and chiller' standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones) when 'Fan coil chiller with no heat' standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones) when 'Baseboard district hot water heat' standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, zones) when 'Baseboard district hot water heat with direct evap coolers' standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, zones) standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', zones) when 'Baseboard electric heat' standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, zones) when 'Baseboard electric heat with direct evap coolers' standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, zones) standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', zones) when 'Baseboard hot water heat' standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, zones) when 'Baseboard hot water heat with direct evap coolers' standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, zones) standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', zones) when 'Window AC with no heat' standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', zones) when 'Window AC with forced air furnace' standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Forced Air Furnace', ht = 'NaturalGas', znht = nil, cl = nil, zones) when 'Window AC with district hot water baseboard heat' standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, zones) when 'Window AC with hot water baseboard heat' standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, zones) when 'Window AC with electric baseboard heat' standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, zones) when 'Window AC with unit heaters' standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, zones) when 'Direct evap coolers' standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', zones) when 'Direct evap coolers with unit heaters' standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, zones) when 'Unit heaters' standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, zones) when 'Heat pump heat with no cooling' standard.model_add_hvac_system(self, 'Residential Air Source Heat Pump', ht = nil, znht = nil, cl = 'Electricity', zones) when 'Heat pump heat with direct evap cooler' # standard.model_add_hvac_system(self, 'Residential Air Source Heat Pump', ht=nil, znht=nil, cl='Electricity', zones) # Using PTHP to represent zone heat pump for this configuration # because only one airloop may be connected to each thermal zone. standard.model_add_hvac_system(self, 'PTHP', ht = 'Electricity', znht = nil, cl = 'Electricity', zones) # disable the cooling coils in all the PTHPs getZoneHVACPackagedTerminalHeatPumps.each do |pthp| clg_coil = pthp.heatingCoil.to_CoilHeatingDXSingleSpeed.get clg_coil.setAvailabilitySchedule(alwaysOffDiscreteSchedule) end standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', zones) when 'VAV with reheat' standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'Electricity', zones) when 'VAV with PFP boxes' standard.model_add_hvac_system(self, 'VAV PFP Boxes', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'Electricity', zones) when 'VAV with gas reheat' standard.model_add_hvac_system(self, 'VAV Gas Reheat', ht = 'NaturalGas', ht = 'NaturalGas', cl = 'Electricity', zones) when 'VAV with zone unit heaters' standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, zones) when 'VAV with electric baseboard heat' standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, zones) when 'VAV cool with zone heat pump heat' standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones) # standard.model_add_hvac_system(self, 'Residential Air Source Heat Pump', ht=nil, znht=nil, cl='Electricity', zones) # Using PTHP to represent zone heat pump for this configuration # because only one airloop may be connected to each thermal zone. standard.model_add_hvac_system(self, 'PTHP', ht = 'Electricity', znht = nil, cl = 'Electricity', zones) # disable the cooling coils in all the PTHPs getZoneHVACPackagedTerminalHeatPumps.each do |pthp| clg_coil = pthp.heatingCoil.to_CoilHeatingDXSingleSpeed.get clg_coil.setAvailabilitySchedule(alwaysOffDiscreteSchedule) end when 'PVAV with reheat', 'Packaged VAV Air Loop with Boiler' # second enumeration for backwards compatibility with Tenant Star project standard.model_add_hvac_system(self, 'PVAV Reheat', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'Electricity', zones) when 'PVAV with PFP boxes' standard.model_add_hvac_system(self, 'PVAV PFP Boxes', ht = 'Electricity', znht = 'Electricity', cl = 'Electricity', zones) when 'Residential forced air' standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, zones) when 'Residential forced air cooling hot water baseboard heat' standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, zones) when 'Residential forced air with district hot water' standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = 'Electricity', zones) when 'Residential heat pump' standard.model_add_hvac_system(self, 'Residential Air Source Heat Pump', ht = 'Electricity', znht = nil, cl = 'Electricity', zones) when 'Forced air furnace' standard.model_add_hvac_system(self, 'Forced Air Furnace', ht = 'NaturalGas', znht = nil, cl = nil, zones) when 'Forced air furnace district chilled water fan coil' standard.model_add_hvac_system(self, 'Forced Air Furnace', ht = 'NaturalGas', znht = nil, cl = nil, zones) standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones) when 'Forced air furnace direct evap cooler' # standard.model_add_hvac_system(self, 'Forced Air Furnace', ht='NaturalGas', znht=nil, cl=nil, zones) # Using unit heater to represent forced air furnace for this configuration # because only one airloop may be connected to each thermal zone. standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, zones) standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', zones) when 'Residential AC with no heat' standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = 'Electricity', zones) when 'Residential AC with electric baseboard heat' standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, zones) else puts "HVAC system type '#{system_type}' not recognized" end end |